Waking the building
KELO connects the equipment buildings already have, adds intelligence at the edge, and turns spare capacity into AI compute.
Equipment runs without anyone seeing how it behaves, until something fails or the energy bill arrives.
The Universal Building Automation Gateway brings them into the KELO Managed Edge, with local AI inference on the device, so decisions don't wait for the cloud.
Energy prediction, presence, equipment health and automation, managed in KELO Cloud across every site you run.
No rip-and-replace. KELO bridges the devices a building already has, then runs the applications on top.
AI that acts on real equipment needs guardrails. Follow one event on one chiller, from first signal to confirmed result.
Rooftop chiller 2 starts vibrating outside its usual band at 14:06. On its own, it is just one noisy reading.
Vibration, supply temperature and power draw are aligned by time, location and asset, across three different protocols.
A local model running on the gateway flags likely bearing wear and estimates remaining useful life, without a cloud round trip.
The workflow lowers the chiller's load to 70% and opens a work order. Rules and permissions decide what AI is allowed to touch.
Vibration returns to normal, the result is checked, and the enriched event goes to KELO Cloud for the whole portfolio to learn from.
Once a building is metered and intelligent, KELO can see something else: electrical capacity that sits idle most of the year.
The glass is the site's electrical service: 1,000 kW. Nothing can go above it.
Each ridge is one day of real demand. Weekends dip, summer climbs, and the highest point is the measured peak.
The gap between the highest day and the service limit is where new load can live safely.
KELO Cloud coordinates building load and AI compute together, so the combined peak stays inside the site's electrical service.
Lower operating costs and new value from the same power, managed from one cloud.
A ~60 kW modular system, deployed and operated by KELO at qualified sites.
Direct liquid cooling at the chip: cool supply in, heat carried straight out.
The CoolPod rejects roughly 205,000 BTU/h, while KELO Cloud watches server health, power and site conditions around the clock.
As GPU generations change, servers swap through the same power and cooling connection.
Illustrative figures. Planning envelopes, not specifications.
Move the sliders to your electrical service and measured peak. We keep a safety margin and match it to KELO's compute family.
Illustrative estimate only. A real site power review also checks voltage, panel space, cooling and combined peak.
KELO deploys and operates every system. On-site work is scheduled only when it is needed.
Electrical service, space, cooling, connectivity and access.
Feeder design, heat rejection and approvals with the engineer of record.
Compute, gateways, meters and sensors, verified before handover.
KELO Cloud watches server health, power and site conditions.
New GPU generations through the same power and cooling interface.